The InBody Fall Risk Assessment (FRA) identifies fall risks and evaluates balance, particularly benefiting elderly patients. With up to 80% of falls preventable, the FRA helps medical professionals detect and manage fall risks proactively. By assessing balance and pinpointing factors like leg strength, the FRA supports effective fall prevention with personalized care plans.

The InBody Fall Risk Assessment (FRA) identifies fall risks and evaluates balance, particularly benefiting elderly patients. With up to 80% of falls preventable, the FRA helps medical professionals detect and manage fall risks proactively. By assessing balance and pinpointing factors like leg strength, the FRA supports effective fall prevention with personalized care plans.






We have chosen the InBody Fall Risk Assessment (FRA) system for its comprehensive evaluation of fall risk, analyzing body balance, lower limb muscle mass, and leg strength. Unlike other tools, the FRA provides an intuitive score that allows for easy tracking of balance changes and proactive management of risk factors. This system will be instrumental in our research, which focuses not only on fall prevention in older adults but also on implementing long-term strategies for middle-aged adults. The FRA will help us better understand key risk factors and improve prevention efforts across different age groups.
Prof. Ho Han, PhD
Oklahoma State University



| Kiosk Dimensions | 24.80 (L) × 22.83 (W) × 63.78 (H) : in |
|---|---|
| Footplate Dimensions | 36.42 (L) × 32.76 (W) × 34.45 (H) : in |
| Measurement Method | Weight is measured on the four load cells of the footplate |
| Display | 19inch Color Touch Monitor |
| Measurement Range | 11 ~ 331 lb |
| Product Weight | Kiosk: 118 lb Footplate: 93.70 lb |
| Power Source | AC 100-240V, 50-60Hz 1.2A |
| Consumption | 100VA |
| Printer | Laser/Inkjet printers (recommended by InBody Co., Ltd.) * Check http://www.inbodyservice.com for printer types Device size |
| Input Interface | Touch Screen |
| External Interface | RS-232C 2EA, USB 2.0 Host 1EA, USB 3.0 Host 2EA, LAN 2EA |
| Operating Environment | 50 ~ 104°F, Humidity: 30 ~ 75%, Air Pressure: 70 ~ 106 kPa |
| Storage Environment | 14 ~ 140°F, Humidity: 10 ~ 80%, Air Pressure: 50 ~ 106 kPa (No Condensation) |
| Result Items | Shaking Index, Sensory System Score, Sensory System Evaluation, Somatosensory
Evaluation, Visual Evaluation, Vestibular Sense Evaluation, Response Time, Posture
Holding Time, Nervous System Score, Nervous System Evaluation, Response Time
Evaluation, Posture Holding Time Evaluation,Integrated Balance Capability Analysis
Score, Integrated Balance Capability Evaluation, Comprehensive Score, Fall Risk Analysis * When InBody and IB-LS are linked: right leg muscle mass, left leg muscle mass, muscle mass left/right balance, right leg muscle strength, left leg muscle strength, muscle strength left/right balance, musculoskeletal score, leg muscle mass evaluation, left/right balance evaluation of leg muscle mass, leg strength evaluation, left-right balance evaluation of leg strength |