
Designed for people who are immobile or have amputated limbs, the InBody S10 features attachable electrodes and swivel casters for accurate, convenient, and non-invasive body composition and body water analysis. Get double the outputs with standard data like Percent Body Fat and Skeletal Muscle Mass, plus a Result Sheet just for body water analysis and advanced metrics like Whole Body Phase Angle.

Designed for people who are immobile or have amputated limbs, the InBody S10 features attachable electrodes and swivel casters for accurate, convenient, and non-invasive body composition and body water analysis. Get double the outputs with standard data like Percent Body Fat and Skeletal Muscle Mass, plus a Result Sheet just for body water analysis and advanced metrics like Whole Body Phase Angle.

Engineered for exceptional reproducibility and accuracy, it’s the ideal choice for patient assessments. Designed with versatility in mind, these electrodes are perfect for patients who may struggle with traditional clamp or adhesive electrodes.


Additionally, InBody S10 can be used for a broader range of subjects, including amputee patients. The InBody results remain accessible for this patient group as well.

Research Outcome:
Lower phase angle is associated with reduced strength and balance, while higher impedance ratio correlates with increased fear of falling in older women.
Output Used:
PhA
Key outcomes:
Key Parameters Used:
PhA
Patients Group:
No. of Patients:
85
Sterner, D., et al – 2024
Institute of Exercise Physiology and Rehabilitation Science, UCF.
Physiology of Work and Exercise Response (POWER) Lab
Research Outcome:
BIA detects significant changes in body composition, including increased lean mass and fluid mass, during the immediate peri-operative period following total joint arthroplasty, aiding post-operative assessment.
Output Used:
LBM
Key outcomes:
Key Parameters Used:
LBM
Patients Group:
No. of Patients:
67
Marinier, M., et al – 2022
University of Iowa
Department of Orthopedics and Rehabilitation
Research Outcome:
Older adults with femoral fragility fractures experience significant skeletal muscle loss, which persists over time and negatively impacts physical function, regardless of baseline nutritional status.
Output Used:
SMI, SMM
Key outcomes:
Key Parameters Used:
SMI, SMM
Patients Group:
No. of Patients:
90
Willey, M., et al – 2023
University of Iowa Hospitals and Clinics
Research Outcome:
Acute normobaric and hypobaric hypoxia both affect muscle and brain oxygenation, cardiovascular response, and fluid regulation, with hypobaric hypoxia causing greater cardiovascular compensation.
Output Used:
ECW, ICW, TBW
Key outcomes:
Key Parameters Used:
ECW, ICW, TBW
Patients Group:
No. of Patients:
18
Rosales, A., et al – 2022
University of Nebraska at Omaha
School of Health and Kinesiology
Research Outcome:
Higher physical activity and lower sedentary behavior in older women are linked to better body composition and lower fall risk.
Output Used:
SMI, BFM
Key outcomes:
“Compared to the inactive-high sedentary group, more favorable body composition and dynamic balance results were found in:
Inactive-low sedentary groups:
“Physical activity (PA) programs focusing on concurrently achieving sufficient moderate-to-vigorous PA and reduced sedentary behavior might promote a healthy body composition and reduced fall risk among older adults.”
Key Parameters Used:
SMI, BFM
Patients Group:
No. of Patients:
94
Choudhury, R., et al- 2023
| Bioelectrical Impedance (BIA) Measurement Items | Bioelectrical impedance (Z) - 30 Impedance Measurements by Using 6 Different Frequencies (1kHz, 5kHz, 50kHz, 250kHz, 500kHz, 1000kHz) at Each of 5 Segments (Right Arm, Left Arm, Trunk, Right Leg and Left Leg) |
|---|---|
| Reactance (Xc) - 15 Impedance Measurements by Using 3 Different Frequencies (5kHz, 50kHz, 250kHz,) at Each of 5 Segments (Right Arm, Left Arm, Trunk, Right Leg, and Left Leg) | |
| Electrode Method | Touch Type / Adhesive Electrode System |
| Measurement Method | Direct Segmental Multi-frequency Bioelectrical Impedance Analysis Method, DSM-BIA method |
| Body Composition Calculation Method | No use of Empirical Estimation |
| Outputs (Body Water Results Sheet) | Intercellular Water, Extracellular Water, Total Body Water, ECW/TBW, Segmental Body Water Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Segmental ECW/TBW Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Body Water Composition History (Weight, Total Body Water, Intracellular Water, Extracellular Water, ECW/TBW), Segmental ICW Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Segmental ECW Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Dry Lean Mass, Lean Body Mass, Body Fat Mass, Weight, Skeletal Muscle Mass, Body Mass Index, Percent Body Fat, Basal Metabolic Rate, Visceral Fat Level, Reactance (5kHz,50kHz, 250kHz), Whole Body Phase Angle (50kHz, Right side of the body), Segmental Phase Angle (50kHz, Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Impedance at each segment/frequency |
| Outputs (Body Composition Results Sheet) | Intercellular Water, Extracellular Water, Total Body Water, Dry Lean Mass, Lean Body Mass, Body Fat Mass, Weight, Skeletal Muscle Mass, Body Mass Index, Percent Body Fat, Segmental Lean Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), Segmental ECW/TBW Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg), ECW/TBW, Body Composition History (Weight, Skeletal Muscle Mass, Percent Body Fat, ECW/TBW), Visceral Fat Area, Body Fat-Lean Body Mass Control, Segmental Fat Analysis (Right Arm, Left Arm, Trunk,Right Leg, Left Leg), Basal Metabolic Rate, Leg Lean Mass, TBW/LBM, Reactance (5kHz,50kHz, 250kHz), Whole Body Phase Angle (50kHz, Right side of the body), Segmental Phase Angle (5kHz, 50kHz, 250kHz, Right Arm, Left Arm, Trunk, Right Leg, Left Leg) Impedance at each segment/frequency |
| Check the results | LCD screen, web, member management PC program LookinBody |
| Logo Display | Possible to input name of the user’s place, address and contact number |
| Results Sheet | Body Water Results Sheet, Body Composition Results Sheet |
| Portability | Indoors - with own cart, Outdoors - with own carrying case. |
| Posture | Lying Posture, Seated Posture, Standing Posture |
| Electrode Type | Touch Type, Adhesive Type |
| Setting of Dialysis Mode | Measurement time(before/during/after dialysis), Access position, Paralyzed position set available |
| Data Storage | Possible to save the results when ID is entered (Up to 100,000 measurements) |
| User’s Interface | Touch screen and key pad |
| Use of USB Storage Device | Possible to backup and transfer data to USB storage device (compatible with Excel and Lookin’Body software) It is recommended to use the USB storage device provided by InBody. |
| Data Back-Up | Possible to backup data through USB storage device and to restore the data to the InBody |
| Printer Connection | USB port |
| Applied Rating Current | Under 100μA(1kHz), 500μA(over 5kHz) |
| Power Consumption | 50VA |
| Display Type | 800 × 480 Touch Color LCD |
| External Interface | RS-232C 1EA, USB Slave 1EA, USB Host 1EA |
| Compatible Printer | Laser/Inkjet PCL 3 or above and SPL (Printer recommended by InBody) |
| Operation Environment | 50 ~ 104°F (10 ~ 40°C), 30 ~ 75%RH, 70 ~ 106kPa |
| Storage Environment | 14 ~ 158°F (-10 ~ 70°C), 10 ~ 80%RH, 50 ~ 106kPa (No condensation) |
| Test Duration | 90 - 130 Seconds |
| Age Range | 3+ Years |
| Compatible Software | LookinBody120 |
| Height Range | 3 ft 1.4 in – 7 ft 2.6 in |
| Weight Range | 22 – 551 lb |
| Compatible Accessories | Body Composition Result Sheet, Body Water Result Sheet, USB Drive, Cart, External Battery, Carrying Case, InBody Tissues, Laser/Ink Jet Printer, Poster |
| Equipment Weight | 4.4 lbs |
| Dimensions | 12.7(L) × 8(W) × 2.1(H): inch 322(L) × 202(W) × 53(H): mm |
| Database | 100,000 results (if member ID is utilized) |
| Warranty | 1-Year Manufacturer’s Warranty |