InBody continues to work closely with academic researchers on a global scale to develop more in-depth clinical applications of body composition. With our long history in the industry, we provide more than 7,000 research publications.
Use the search box below to find key terms in research papers. For category-specific or recommended results, use the dropdown lists provided.
Research title with ★ indicates InBody recommended paper.
Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmo
Principle/Accuracy | PBF | P.R. von Hurst et al. | 2016 | New Zealand | NUTRITION & DIETETICS
Air displacement plethysmography (ADP) and dual‐energy X‐ray absorptiometry (DXA) are well‐regarded methods for predicting body fat percentage (BF%). Bioelectrical impedance analysis (BIA) also predicts BF% and has distinct advantages in research settings. Aim To assess the validity of BIA against ADP and DXA to measure BF%, and to test the reliability of each method. Methods Adults (n= 166) with a wide range of body mass index (19–38 kg/m2) were tested twice during a 5‐day period. ADP was conducted in a BodPod (Life …
Cross-calibration of eight-polar bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for the assessment of
Principle/Accuracy | FFM, Appendicular FFM | M. Malavolti et al.(Bedogni) | 2003 | Italy | Annals of Human Biology
Aim: To calibrate eight-polar bioelectrical impedance analysis (BIA) against dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition in healthy adults. Research design: A cross-sectional study was carried out. Subjects: Sixty-eight females and 42 males aged 21-82 years participated in the study. Methods: Whole-body fat-free mass (FFM) and appendicular lean tissue mass (LTM) were measured by DXA; resistance (R) of arms, trunk and legs was measured by eight-polar BIA at frequencies of 5 …
Estimation of prevalence of sarcopenia by using a new bioelectrical impedance analysis in Chinese community-dwelling elderly pe
Principle/Accuracy | ASM | Hui Wang et al. | 2016 | China | BMC geriatrics
The aim of the present study was to validate the usefulness of the new octapolar multifrequency bioelectrical impedance analysis (BIA) for assessment of appendicular skeletal muscle mass (ASM) by comparing it with that of dual-energy X-ray absorptiometry (DXA) and to investigate the prevalence of sarcopenia in Chinese community-dwelling elderly according to Asian Working Group for Sarcopenia (AWGS) definition. A cross-sectional study was conducted in communities of Chengdu, China. A total of 944 community …
Reliability and agreement of various InBody body composition analyzers as compared to dual-energy X-ray absorptiometry in healt
Principle/Accuracy | FFM, FM, PBF | McLester et al | 2018 | USA | Journal of Clinical Densitometry
Background: Bioelectrical impedance analysis has evolved over the years to include the use of multiple frequencies and impedance measurements to improve the accuracy and reliability of body composition estimates. The purpose of this investigation was to evaluate the reliability of the InBody 230, InBody 720, and InBody 770 to measure body fat percent (BF%), fat mass (FM), and fat-free mass (FFM) in the general population and to compare results to dual-energy X-ray absorptiometry (DXA). Methods: A total of 31 males and 36 …
Comparison of Lower Extremity Lean Mass Between Multi-frequency Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorpti
Principle/Accuracy | ASM, LBM | Montgomery et al. | 2019 | USA | Athletic Training and Sports Health Care
Purpose: To compare lower extremity lean mass (LELM) and lean body mass (LBM) between bioelectrical impedance analysis (BIA) devices and dual-energy x-ray absorptiometry (DXA). Methods: Thirty-one women and 26 men underwent body composition testing. Inter-instrument reliability and bias were assessed with intraclass correlation coefficients and t tests, respectively. Results: Systematic underestimation bias for LELM was observed in men (approximately 3 kg) and women (approximately 1.5 kg)(both …
Comparison of body composition assessed by multi-frequency segmental bioelectrical impedance analysis and dual energy X-ray abs
Principle/Accuracy | FFM, Segmental FFM, FM, BMC | Najafi MT et al. | 2018 | Iran | Nephro-Urology Monthly
Background: The assessment of body composition during the course of treatment of hemodialysis patients is crucial for optimal treatment. We intended to assess the diagnostic performance of bioelectrical impedance analysis (BIA), which could be used at the bedside in dialysis wards, and compare it with the results of dual-energy X-ray absorptiometry (DEXA). Methods: In a cross-sectional study, 43 patients with end-stage renal disease (ESRD) after hemodialysis sessions underwent direct segmental multi-frequency BIA …